View and Download Aquabot Robotic Pool Cleaner operating instructions manual online. Robotic Pool Cleaner. Robotic Pool Cleaner swimming pool vacuum pdf manual download. Aquabot parts repair almost always involves direct parts replacement. Use the search box to search this site for a specific topic. Working on the robot is not hard, but it can be tedious. Aquabot parts repair can be very easy if you follow several easy steps. MerCruiser Repair Manual 454 & 502 7.4L/8.2L. 1998-2002 MerCruiser Repair Manual D7.3L V8 Diesel. 1998-2003 MerCruiser Repair Manual 3.0L. 2000-2008 MerCruiser Repair Manual D1.7L DTI. 2000-2005 MerCruiser Repair Manual Bravo & Sport. DOWNLOAD MERCRUISER ENGINE & STERNDRIVE REPAIR MANUALS Aquabot Bravo Manual Please carefully.

It is unlikely that both Motors (Drive Motor – Ref.# 1.15 and Pump Motor – Ref.# 1.14) are experiencing mechanical problems. In most cases the issue lies with something that is hindering the flow of electricity from the electrical outlet to the Power Supply (Figure 4) or through the Floating Cable (Ref.# 3.1) to the Aquabot itself. To locate and resolve where electrical flow is being hindered check the following.

Electrical Outlet & Connections – Make sure that the Power Supply is firmly plugged into a grounded electrical outlet which has power. To test the outlet, plug in another electrical instrument that you know works to the outlet.

Aquabot bravo partsAquabot bravo repair manual transmission

Aquabot Iii Bravo

Repair

Check that the Floating Cable is securely plugged into the Power Supply.

Power Supply

Aquabot Bravo Parts

  • Check that the Power Supply button is pressed upwards to the “ON” position. Note: Some models have a Reset (Safety) Switch, which must be pressed each time you press the “ON” button.
  • Switch the Power Supply “Off” and “On” several times, allowing approximately 30 seconds between each“ON” and “OFF”. Remember, if your Aquabot comes equipped with a Reset Switch it must be pressed each time after pressing the “ON” button.
  • Unplug the Power Supply from the electrical outlet. Check that the Fuse in the Power Supply’s Fuse Holder (Ref.# 4.4) appears operational. If the Fuse appears burned out, then replace it with a 5 AMP SLO BLOW Fuse Please note that there are various Power Supply model types and the location of the Fuse may be in either the front or the back of your Power Supply.
  • Use a cotton swab to dry all sides of the Fuse and Fuse Holder (inside and out). Cable Assemblies – With the Power Supply unplugged, check the Power Cable (Ref.# 4.6) and the Floating Cable for cuts or damage. If you detect damage to either Cable, please contact our Customer Service Department at 1-800-845-4856.